8025HR-1 CMS & EFF

8025HR-1 CMS & EFF
Design Criteria
psi
40 50 60 70
#24 Nozzle (3/8")  
Flow (gpm) 25.2 28.2  30.9  33.3 
Diameter at 1.5 ft ht (ft) 134 144  154  159 
#26 Nozzle (13/32")  
Flow (gpm) 29.3  32.7  35.9  38.7
Diameter at 1.5 ft ht (ft) 142 152 161 166 
#28 Nozzle (7/16")  
Flow (gpm) 33.9 38.0  41.6 44.9 
Diameter at 1.5 ft ht (ft) 148 157  166 171 
#30 Nozzle (15/32")  
Flow (gpm) 38.6  43.1  47.2  51.0 
Diameter at 1.5 ft ht (ft) 153 162  170  175
#32 Nozzle (1/2")  
Flow (gpm) 43.9  49.0  53.7  58.0 
Diameter at 1.5 ft ht (ft) 156  165 173 179 
#34 Nozzle (17/32")  
Flow (gpm) 49.5  55.4  60.7  65.5 
Diameter at 1.5 ft ht (ft) 159 168 176 183 
#36 Nozzle (9/16")  
Flow (gpm) 55.5  62.1  68.0  73.5 
Diameter at 1.5 ft ht (ft) 161 170  178  187 
#38 Nozzle (19/32")  
Flow (gpm) 59.9  66.9  73.3  79.2 
Diameter at 1.5 ft ht (ft) 163 172 180  190
#40 Nozzle (5/8")  
Flow (gpm) 67.1  75.0  82.1 88.7
Diameter at 1.5 ft ht (ft) 165 174  182  192 

Sprinkler performance may vary with actual field conditions. Diameters shown are for standard straight bore nozzles and stream straightening vanes. Other nozzles are available. Consult factory for specific performance data. Stream heights range from 12.5 to 28.0 ft above nozzle based on pressure and nozzle size.