PRXF (Metric)

PRXF
DESIGN CRITERIA
Preset Operating Pressure Maximum Inlet Pressure Flow Range Inlet Sizes Outlet Sizes
PRXF10 0.69 bar 6.20 bar 4543 - 18170 L/hr 3" F slip 3" F slip
PRXF15 1.03 bar 6.55 bar 4543 - 19306 L/hr 3" F slip 3" F slip
PRXF20 1.38 bar 6.89 bar 4543 - 20441 L/hr 3" F slip 3" F slip
PRXF25 1.72 bar 7.24 bar 4543 - 21577 L/hr 3" F slip 3" F slip
PRXF30 2.07 bar 7.58 bar 4543 - 22713 L/hr 3" F slip 3" F slip
PRXF35 2.41 bar 7.93 bar 4543 - 22713 L/hr 3" F slip 3" F slip
PRXF40 2.76 bar 8.27 bar 4543 - 22713 L/hr 3" F slip 3" F slip
PRXF50 3.45 bar 8.96 bar 4543 - 22713 L/hr 3" F slip 3" F slip
PRXF60 4.14 bar 9.65 bar 4543 - 22713 L/hr 3" F slip 3" F slip

The pressure regulator shall maintain the predetermined operating pressure provided that the inlet pressure is at least 0.34 bar above the expected outlet pressure, but not exceeding the maximum inlet pressure as shown above.

Recommended for outdoor use only. Not NSF certified.