Senninger’s Extended Flow Pressure-Master Regulator is now available in a new Limit Valve model. The PRXF-LV is designed to limit static (no flow) water pressure between the regulation point and a downstream shut-off valve, thus protecting in-line components.

It can handle flows up to 75 gpm [17034 L/hr]. It is ideal for installations requiring accurate zone pressure regulation. Each regulator maintains a constant preset outlet pressure based on its flow / inlet pressure.

Features

• 100% water tested for accuracy
• Limits downstream pressure to no more than 15 psi above regulated pressure rating during static (no flow) conditions
• Very low hysteresis and friction loss
• Pressures: 30-50 psi (2.07 – 3.45 bar)
• Flows: 15 – 75 gpm (3407 – 17034 L/hr)
• Inlet sizes: 3″ F socket
• Outlet sizes: 3″ F socket
• Backed by 1-year warranty on materials, workmanship and performance

Model # Preset Operating Maximum Inlet Pressure Flow Range
PRXF-LV-30 30 psi
(2.07 bar)
100 psi
(6.90 bar)
15 – 75 gpm
(3407 – 17034L/hr)
PRXF-LV-40 40 psi
(2.76 bar)
125 psi
(8.62 bar)
15 – 75 gpm
(3407 – 17034L/hr)
PRXF-LV-50 50 psi
(3.45 bar)
125 psi
(8.62 bar)
15 – 75 gpm
(3407 – 17034L/hr)

Caution: